This NIP defines the basic protocol that should be implemented by everybody. New NIPs may add new optional (or mandatory) fields and messages and features to the structures and flows described here.
Each user has a keypair. Signatures, public key, and encodings are done according to the [Schnorr signatures standard for the curve `secp256k1`](https://bips.xyz/340).
To obtain the `event.id`, we `sha256` the serialized event. The serialization is done over the UTF-8 JSON-serialized string (which is described below) of the following structure:
The first element of the tag array is referred to as the tag _name_ or _key_ and the second as the tag _value_. So we can safely say that the event above has an `e` tag set to `"5c83da77af1dec6d7289834998ad7aafbd9e2191396d75ec3cc27f5a77226f36"`, an `alt` tag set to `"reply"` and so on. All elements after the second do not have a conventional name.
As a convention, all single-letter (only english alphabet letters: a-z, A-Z) key tags are expected to be indexed by relays, such that it is possible, for example, to query or subscribe to events that reference the event `"5c83da77af1dec6d7289834998ad7aafbd9e2191396d75ec3cc27f5a77226f36"` by using the `{"#e": ["5c83da77af1dec6d7289834998ad7aafbd9e2191396d75ec3cc27f5a77226f36"]}` filter.
Kinds specify how clients should interpret the meaning of each event and the other fields of each event (e.g. an `"r"` tag may have a meaning in an event of kind 1 and an entirely different meaning in an event of kind 10002). Each NIP may define the meaning of a set of kinds that weren't defined elsewhere. This NIP defines two basic kinds:
-`0`: **user metadata**: the `content` is set to a stringified JSON object `{name: <username>, about: <string>, picture: <url, string>}` describing the user who created the event. [Extra metadata fields](24.md#kind-0) may be set. A relay may delete older events once it gets a new one for the same pubkey.
-`1`: **text note**: the `content` is set to the **plaintext** content of a note (anything the user wants to say). Content that must be parsed, such as Markdown and HTML, should not be used. Clients should also not parse content as those.
And also a convention for kind ranges that allow for easier experimentation and flexibility of relay implementation:
- for kind `n` such that `1000 <= n < 10000`, events are **regular**, which means they're all expected to be stored by relays.
- for kind `n` such that `10000 <= n < 20000 || n == 0 || n == 3`, events are **replaceable**, which means that, for each combination of `pubkey` and `kind`, only the latest event MUST be stored by relays, older versions MAY be discarded.
- for kind `n` such that `30000 <= n < 40000`, events are **parameterized replaceable**, which means that, for each combination of `pubkey`, `kind` and the `d` tag's first value, only the latest event MUST be stored by relays, older versions MAY be discarded.
In case of replaceable events with the same timestamp, the event with the lowest id (first in lexical order) should be retained, and the other discarded.
When answering to `REQ` messages for replaceable events such as `{"kinds":[0],"authors":[<hex-key>]}`, even if the relay has more than one version stored, it SHOULD return just the latest one.
Relays expose a websocket endpoint to which clients can connect. Clients SHOULD open a single websocket connection to each relay and use it for all their subscriptions. Relays MAY limit number of connections from specific IP/client/etc.
The `<subscription_id>` is an arbitrary, non-empty string of max length 64 chars generated by the client. It represents a subscription per connection. Relays MUST manage `<subscription_id>`s independently for each WebSocket connection. `<subscription_id>`s are not guaranteed to be globally unique.
`<filtersX>` is a JSON object containing filter attributes to determine which events will be sent in that subscription. The possible attributes are listed below, and they are filtered with logical AND. If an attribute contains a list (JSON array), the list is filtered with logical OR.
Upon receiving a `REQ` message, the relay SHOULD query its internal database and return events that match the filter, then store that filter and send again all future events it receives to that same websocket until the websocket is closed. The `CLOSE` event is received with the same `<subscription_id>` or a new `REQ` is sent using the same `<subscription_id>`, in which case relay MUST overwrite the previous subscription.
A `REQ` message may contain multiple filters. In this case, events that match any of the filters are to be returned, i.e., multiple filters are to be interpreted as `||` conditions.
The `limit` property of a filter is only valid for the initial query and MUST be ignored afterwards. When `limit: n` is present it is assumed that the events returned in the initial query will be the last `n` events ordered by the `created_at`. It is acceptable to return fewer events than `limit` specifies, but it is expected that relays do not return (much) more events than requested, to avoid clients getting overwhelmed by data.
-`EVENT` messages MUST be sent only with a subscription ID related to a subscription previously initiated by the client (using the `REQ` message above).
-`OK` messages MUST be sent in response to `EVENT` messages received from clients, they must have the 3rd parameter set to `true` when an event has been accepted by the relay, `false` otherwise. The 4th parameter MUST always be present, but MAY be an empty string when the 3rd is `true`, otherwise it MUST be a string formed by a machine-readable single-word prefix followed by a `:` and then a human-readable message. Some examples:
-`CLOSED` messages MUST be sent in response to a `REQ` when the relay refuses to fulfill it. It can also be sent when a relay decides to kill a subscription on its side before a client has disconnected or sent a `CLOSE`. This message uses the same pattern of `OK` messages with the machine-readable prefix and human-readable message. Some examples:
*`["CLOSED", "sub1", "error: could not connect to the database"]`
*`["CLOSED", "sub1", "error: shutting down idle subscription"]`
- The standardized machine-readable prefixes for `OK` and `CLOSED` are: `duplicate`, `pow`, `blocked`, `rate-limited`, `invalid`, and `error` for when none of that fits.